FIRST INSTALLATION RECOMMENDATIONS
ENG
15
Axel Technology srl
www.axeltechnology.com
10.3 FUSE REPLACEMENT
The power supply socket has an integral fuse drawer containing the AC power fuse and a spare, both of the same value.
BEFORE REPLACING THE POWER FUSE, MAKE SURE YOU HAVE THE RIGHT TYPE OF FUSE FOR
THE VOLTAGE TO BE PROTECTED.
USING WRONG FUSE TYPE WILL RESULT IN INSUFFICIENT PROTECTION.
Make sure that the power is switched off and the power cable is disconnected from the equipment.
a.
Open the fuse drawer using a small blade screwdriver.
b. Replace the fuse located at the internal position
c. Push the fuse socket back into the original position (a.)
Perform the set-up under static control conditions. Static charges are likely to completely destroy one or
more of the CMOS semiconductors employed in the unit. Static damage will not be covered under
warranty
Basic damage prevention consists of minimizing generation, discharging any accumulated static charge
on your body and preventing that discharge from being sent to or through any electronic component.
.
Uninsulated dangerous voltage are inside the enclosure, voltage that may be sufficient to constitute a
risk of shock.
Always disconnect to AC Mains before removing the top cover