Barracuda Networks SP4 Uživatelský manuál Strana 118

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 118
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 117
ENG
118
Axel Technology srl
www.axeltechnology.com
LOOP-THROUGH MODE
In the loop-through mode, the output of the stereo generator is directly cabled at the AUX 1 input of RDS encoder. The
RDS output of the encoder will be then connected to the normal composite/Mpx input of the FM exciter.
As noticed, this configuration is NOT recommended, as the composite / MPX is passing through the RDS encoder and
program transmission will be interrupted in the event of RDS encoder failure. This configuration doesn’t need to alter the
encoder factory preset. RDS subcarrier phase will be locked either to external FM stereo MPX signal. Correct
synchronization will cause MPX LED ON in the front panel.
External Synch MUST be enabled from the control panel menu or from the Pc control software
MPX pilot suitable level: minimum 100 mVpp, max 1,9 Vpp
19 kHz Sync tolerance : +/- 5Hz to lock; +/- 15 Hz to unlock
An automatic switchover to internal oscillator in case of absence or l
ow quality of external reference
signal is performed.
The level of the injected signal may be adjusted by means of the trimmer next to the corresponding
BNC connector (no software control is provided for this purpose). This trimmer is factory preset for a
gain of 0 dB (unity gain).
- The END -
Zobrazit stránku 117
1 2 ... 113 114 115 116 117 118

Komentáře k této Příručce

Žádné komentáře